gas: fix symbol value calculation for versioned symbol aliases

Symbol value is in bytes while fragS::fr_address is in octets. Fixes GAS
symver12 and symver13 tests on ELF targets with with OCTETS_PER_BYTE>1.

	* config/obj-elf (elf_frob_symbol): Fix symbol value calculation
	for versioned symbol aliases.

Signed-off-by: Christian Eggers <ceggers@gmx.de>
This commit is contained in:
Christian Eggers
2020-11-01 09:10:14 +01:00
committed by Alan Modra
parent 706d7ce948
commit 05862db73f
2 changed files with 7 additions and 1 deletions

View File

@@ -2588,7 +2588,8 @@ elf_frob_symbol (symbolS *symp, int *puntp)
because we are in the middle of the final loop. */
S_SET_VALUE (symp2,
(S_GET_VALUE (symp)
- symbol_get_frag (symp)->fr_address));
- (symbol_get_frag (symp)->fr_address
/ OCTETS_PER_BYTE)));
symbol_set_frag (symp2, symbol_get_frag (symp));