@chapter HP-7100 Timing Data
|
|
|
|
@section Introduction
|
|
|
|
The timing data for the PA-RISC version of RTEMS is
|
|
provided along with the target dependent aspects concerning the
|
|
gathering of the timing data. The hardware platform used to
|
|
gather the times is described to give the reader a better
|
|
understanding of each directive time provided. Also, provided
|
|
is a description of the interrupt latency and the context
|
|
switch times as they pertain to the PA-RISC version of RTEMS.
|
|
|
|
@section Hardware Platform
|
|
|
|
No directive execution times are reported for the
|
|
HP-7100 because the target platform was proprietary and
|
|
executions times could not be released.
|
|
|
|
@section Interrupt Latency
|
|
|
|
The maximum period with traps disabled or the
|
|
processor interrupt level set to it's highest value inside RTEMS
|
|
is less than RTEMS_MAXIMUM_DISABLE_PERIOD
|
|
microseconds including the instructions which
|
|
disable and re-enable interrupts. The time required for the
|
|
HP-7100 to vector an interrupt and for the RTEMS entry overhead
|
|
before invoking the user's trap handler are a total of
|
|
RTEMS_INTR_ENTRY_RETURNS_TO_PREEMPTING_TASK
|
|
microseconds. These combine to yield a worst case interrupt
|
|
latency of less than RTEMS_MAXIMUM_DISABLE_PERIOD +
|
|
RTEMS_INTR_ENTRY_RETURNS_TO_PREEMPTING_TASK microseconds at 15 Mhz.
|
|
[NOTE: The maximum period with interrupts disabled was last
|
|
determined for Release RTEMS_RELEASE_FOR_MAXIMUM_DISABLE_PERIOD.]
|
|
|
|
It should be noted again that the maximum period with
|
|
interrupts disabled within RTEMS for the HP-7100 is hand calculated.
|
|
|
|
@section Context Switch
|
|
|
|
The RTEMS processor context switch time is RTEMS_NO_FP_CONTEXTS
|
|
microsections for the HP-7100 when no floating point context
|
|
switch is saved or restored. Saving and restoring the floating
|
|
point context adds additional time to the context
|
|
switch procedure. Additional execution time is required when a
|
|
TASK_SWITCH user extension is configured. The use of the
|
|
TASK_SWITCH extension is application dependent. Thus, its
|
|
execution time is not considered part of the raw context switch
|
|
time.
|
|
|
|
Since RTEMS was designed specifically for embedded
|
|
missile applications which are floating point intensive, the
|
|
executive is optimized to avoid unnecessarily saving and
|
|
restoring the state of the numeric coprocessor. On many
|
|
processors, the state of the numeric coprocessor is only saved
|
|
when an FLOATING_POINT task is dispatched and that task was not
|
|
the last task to utilize the coprocessor. In a system with only
|
|
one FLOATING_POINT task, the state of the numeric coprocessor
|
|
will never be saved or restored. When the first FLOATING_POINT
|
|
task is dispatched, RTEMS does not need to save the current
|
|
state of the numeric coprocessor. As discussed in the Register
|
|
Usage section, on the HP-7100 the every task is considered to be
|
|
floating point registers and , as a rsule, every context switch
|
|
involves saving and restoring the state of the floating point
|
|
unit.
|
|
|
|
The following table summarizes the context switch
|
|
times for the HP-7100 processor:
|
|
|
|
@example
|
|
no times are available for the HP-7100
|
|
@end example
|
|
|
|
@section Directive Times
|
|
|
|
No execution times are available for the HP-7100
|
|
because the target platform was proprietary and no timing
|
|
information could be released.
|
|
|