@@ -9,12 +9,14 @@ The hardware Ethernet address is not set at the factory. It is the
|
|||||||
responsibility of the end-user to insure that it is set properly.
|
responsibility of the end-user to insure that it is set properly.
|
||||||
This file describes the standard procedure recommended by DY-4
|
This file describes the standard procedure recommended by DY-4
|
||||||
technical support for setting this address. This procedure is
|
technical support for setting this address. This procedure is
|
||||||
compatible with that followed by VxWorks and is documented in
|
similar to that followed by VxWorks as documented in DY-4
|
||||||
DY-4 Document Number #807885.
|
Document Number #807885.
|
||||||
|
|
||||||
EEPROM non-volatile memory of the SVME/DMV-176/177. The FFW
|
The hardware Ethernet address and OS configuration information
|
||||||
reserves 256 bytes of the SEEPROM for its own use and the remaining
|
must be stored in the SEEPROM non-volatile memory of the
|
||||||
remaining 256 bytes is reserved for OS specific information.
|
SVME/DMV-176/177. The Foundation Firmware (FFW) reserves the
|
||||||
|
first 256 bytes of the SEEPROM for its own use and the remaining
|
||||||
|
remaining 256 bytes are available for OS specific information.
|
||||||
|
|
||||||
Three bytes in the Serial EEPROM are used for the lowest three bytes
|
Three bytes in the Serial EEPROM are used for the lowest three bytes
|
||||||
of the hardware Ethernet address These should be set to the serial
|
of the hardware Ethernet address These should be set to the serial
|
||||||
@@ -36,27 +38,5 @@ command in the General Purpose Monitor (GPM) can be used to do this.
|
|||||||
In this example we will assume that the serial number of the target card
|
In this example we will assume that the serial number of the target card
|
||||||
is 123456.
|
is 123456.
|
||||||
|
|
||||||
Start VxWorks by entering
|
|
||||||
rts <CR>
|
|
||||||
at the GPM prompt. Stop the auto-booting sequence by pressing any key.
|
|
||||||
The VxWorks prompt appears as:
|
|
||||||
[VxWorks Boot]:
|
|
||||||
Use the N command to modify the SEEPROM as follows:
|
|
||||||
[VxWorks Boot]:N
|
|
||||||
Current Ethernet Address is : 00:80:7f:5a:5a:5a
|
|
||||||
[VxWorks Boot]:N
|
|
||||||
Current Ethernet Address is : 00:80:7f:5a:5a:5a
|
|
||||||
Modify only the last 3 bytes (board unique portion) of the
|
|
||||||
Ethernet Address.
|
|
||||||
The first 3 bytes are fixed at the manufacturer's default
|
|
||||||
address block.
|
|
||||||
00 - 00
|
|
||||||
80 - 80
|
|
||||||
7f - 7f
|
|
||||||
5a - 12
|
|
||||||
5a - 34
|
|
||||||
5a - 56
|
|
||||||
New ethernet address is :00:80:7f:12:34:56
|
|
||||||
[VxWorks Boot]:
|
|
||||||
The SEEPROM is now programmed.
|
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue