Initialized tty->refcount to 0. When (for whatever reason) malloc()
returned a buffer which was not zero-filled, the reference count was not correct. When the application exitted, the "lastClose" handler was not being called to flush the output. This problem had manifested itself on a variety of platforms. The function rtems_termios_dequeue_characters() incorrectly incremented the buffer pointers when it was invoked and there were no characters in the ring buffer. This problem had also manifested itself on a variety of platforms. The symptom was a strange repeating of the data in the transmitter buffer when the transmitter serial device was supposed to go idle.