forked from Imagelibrary/rtems
New file based on email from DY-4 technical support.
This commit is contained in:
62
c/src/lib/libbsp/powerpc/dmv177/README.net
Normal file
62
c/src/lib/libbsp/powerpc/dmv177/README.net
Normal file
@@ -0,0 +1,62 @@
|
||||
#
|
||||
# $Id$
|
||||
#
|
||||
|
||||
Setting the Ethernet Hardware Address
|
||||
=====================================
|
||||
|
||||
The hardware Ethernet address is not set at the factory. It is the
|
||||
responsibility of the end-user to insure that it is set properly.
|
||||
This file describes the standard procedure recommended by DY-4
|
||||
technical support for setting this address. This procedure is
|
||||
compatible with that followed by VxWorks and is documented in
|
||||
DY-4 Document Number #807885.
|
||||
|
||||
EEPROM non-volatile memory of the SVME/DMV-176/177. The FFW
|
||||
reserves 256 bytes of the SEEPROM for its own use and the remaining
|
||||
remaining 256 bytes is reserved for OS specific information.
|
||||
|
||||
Three bytes in the Serial EEPROM are used for the lowest three bytes
|
||||
of the hardware Ethernet address These should be set to the serial
|
||||
number of your SVME/DMV-176/177 card to ensure a unique Ethernet
|
||||
address on your network. The three high bytes are hard coded in the
|
||||
BSP and represent the vendor-specific Ethernet codes (0x00, 0x80, 0x7F).
|
||||
Together these six bytes form the target's Ethernet address.
|
||||
|
||||
NOTE: The serial number is found on the packaging (box) that the
|
||||
board came in OR it is also located on the solder side of the board and
|
||||
looks something like SERNO:XXXXXX. It can not be determined dynamically
|
||||
by software.
|
||||
|
||||
Prior to using the Ethernet controller on the SVME/DMV-176/177 for the
|
||||
first time, the Ethernet address bytes must be programmed into the
|
||||
Serial EEPROM on the target card. The 'emm' (EEPROM Memory Modification)
|
||||
command in the General Purpose Monitor (GPM) can be used to do this.
|
||||
|
||||
In this example we will assume that the serial number of the target card
|
||||
is 123456.
|
||||
|
||||
Start VxWorks by entering
|
||||
rts <CR>
|
||||
at the GPM prompt. Stop the auto-booting sequence by pressing any key.
|
||||
The VxWorks prompt appears as:
|
||||
[VxWorks Boot]:
|
||||
Use the N command to modify the SEEPROM as follows:
|
||||
[VxWorks Boot]:N
|
||||
Current Ethernet Address is : 00:80:7f:5a:5a:5a
|
||||
[VxWorks Boot]:N
|
||||
Current Ethernet Address is : 00:80:7f:5a:5a:5a
|
||||
Modify only the last 3 bytes (board unique portion) of the
|
||||
Ethernet Address.
|
||||
The first 3 bytes are fixed at the manufacturer's default
|
||||
address block.
|
||||
00 - 00
|
||||
80 - 80
|
||||
7f - 7f
|
||||
5a - 12
|
||||
5a - 34
|
||||
5a - 56
|
||||
New ethernet address is :00:80:7f:12:34:56
|
||||
[VxWorks Boot]:
|
||||
The SEEPROM is now programmed.
|
||||
|
||||
Reference in New Issue
Block a user